    The Micro Resistance Slow Lockup Check Valve is a high-precision valve designed to provide controlled backflow prevention with minimal pressure fluctuation. Its slow lockup mechanism reduces water hammer and system stress, ensuring smooth, reliable operation in industrial pipelines, water supply systems, HVAC networks, and chemical processing applications. Constructed from durable materials such as stainless steel, carbon steel, or ductile iron, this valve offers long-term corrosion resistance, energy efficiency, and low maintenance requirements. Ideal for systems requiring precise flow control, gradual closure, and enhanced equipment protection, it enhances both operational safety and pipeline longevity.
  • Share:
  • Contact us Inquiry
  • WhatsApp:+8618953100555

Miaro resistance Slow Lockup Check Valve to use in the feed water pipe, installs uses in water pump outlow point to prevent the me-dium adverse cure-nt and  elimination destuctiveness water hammer,and can the effecive reduoed V-alve  dosure hammer pressure,be p-ossible to safeguard the pipe netwo-rk safe  operation.It has the valve petal lighty,opens in a big way,the eledriaity saving   effe-ct remarkable,fuid resistance small,water hammer eliminati-on organiza-tion  design novel,sealing property stable reliable,the wear-abil-ity,the suitable life  long,the movement noise charaderistic and soo-n are stable,does not have the vibration,does not have.


Technical Data

公称通径DN(mm) Nominal diameter

 

40~800

公称压力PN(MPa) Nominal pressure

 

1.0

 

1.6

 

2.5

 

试验压力

Ps(MPa)

Test pressure

壳体Shell

 

1.5

 

2.4

 

3.75

 

密封Seal

 

1.1

 

1.76

 

2.75

最高工作压力(MPa)

Maximum operating pressure

 

1.0

 

1.6

 

2.5

工作温度

Working temperature

≤80℃根据用户要求可达200℃)

(May reach 200℃ according to user request)

适用介质

Suitable medium

水、弱腐蚀性介质

Water,WeakCorrosion medium


Meterial of main parts

零件名称

Components name

材料名称

Meterial name

阀体、阀盖

Valve body,valve cover

灰铸铁、铸钢

Gray iron,cast steel

阀瓣

Valve petal

橡胶组合件

Rubber Combinationcomponents

阀轴

Valve shaft

不锈钢

Stainless steel


Main dimensions

DN

(mm)

L

H

B

40

200

300

220

50

230

300

270

65

290

320

290

80

310

354

300

100

350

350

320

125

400

380

340

150

480

500

410

200

500

580

450

250

600

670

550

300

700

730

580

350

800

820

630

400

900

920

700

450

1000

950

800

500

1100

1100

900

600

1300

1200

990

700

1400

1550

1120

800

1500

1700

1300


Micro Resistance Slow Lockup Check Valve: Applications, Technical Support, Standards, and Industrial Use

Introduction

The Micro Resistance Slow Lockup Check Valve is a high-performance valve designed to prevent backflow while ensuring a gradual, controlled closure. Its slow lockup feature reduces water hammer, minimizes system stress, and protects sensitive equipment such as pumps and compressors. Constructed from durable materials such as stainless steel, carbon steel, or ductile iron, this valve offers long-term corrosion resistance, energy efficiency, and low maintenance requirements.

This guide covers the valve’s product applications, technical support resources, detection and testing standards, and typical industrial applications, providing a complete reference for engineers, procurement teams, and industrial operators.


Product Applications

1. Backflow Prevention

The valve ensures unidirectional flow, preventing reverse flow that can damage pipelines, pumps, or compressors. Its micro resistance design allows the valve to operate smoothly even under low flow conditions.

2. Water Hammer Mitigation

The slow lockup mechanism significantly reduces the impact of water hammer by controlling the speed at which the valve closes, protecting pipelines from pressure surges.

3. Pressure and Flow Stability

By moderating closure speed, the valve maintains stable system pressure and flow, improving operational efficiency and reducing energy consumption.

4. Typical Fluids Handled

  • Freshwater and municipal water pipelines

  • Industrial fluids, including oils and mild chemicals

  • HVAC systems and cooling water circuits

  • Wastewater and sewage systems


Micro resistance slow lockup check valve

Technical Support

Technical support is critical to ensure proper installation, operation, and maintenance of micro resistance slow lockup check valves.

Installation Guidance

  • Verify flow direction using the arrow on the valve body.

  • Ensure straight pipe lengths upstream and downstream to maintain laminar flow: typically 5–10 diameters upstream and 3–5 downstream.

  • For vertical installations, ensure upward flow for proper operation.

Maintenance Recommendations

  • Inspect the valve disc and seat every 6–12 months.

  • Remove debris or sediment from the internal valve chamber.

  • Lubricate moving parts if required by the manufacturer.

  • Replace worn seals promptly to maintain leak-free operation.

Troubleshooting Tips

ProblemPossible CauseSolution
Valve leaksWorn disc or damaged seatReplace the sealing components
Excessive noiseWater hammer or turbulenceCheck flow velocity and install surge suppressor if needed
Disc stuckDebris or corrosionDisassemble and clean internal components
Short service lifeIncompatible materialUpgrade to corrosion-resistant materials

Detection and Testing Standards

Micro resistance slow lockup check valves are manufactured and tested according to international standards to ensure reliability and performance.

Test TypeDescriptionStandard
Hydrostatic Pressure TestVerifies valve withstands maximum rated pressureISO 5208 / API 598
Leakage TestConfirms tight seal under rated pressureAPI 598
Functional TestEnsures slow closure mechanism operates correctlyManufacturer internal protocols
Material VerificationEnsures corrosion resistance and durabilityASTM / EN material standards

Key Quality Features

  • Pressure and temperature rated according to system requirements.

  • Smooth, controlled closure to prevent water hammer.

  • Corrosion-resistant body and disc materials for long service life.


Applications Across Industries

The micro resistance slow lockup check valve is widely applied in industrial, municipal, and commercial systems.

1. Water Supply and Treatment

  • Prevents backflow in municipal water systems.

  • Reduces pressure surges in pumping stations.

2. HVAC and Cooling Systems

  • Maintains stable flow in heating and cooling pipelines.

  • Prevents equipment damage caused by reverse flow.

3. Industrial Processing

  • Suitable for oil, chemical, and wastewater pipelines.

  • Protects sensitive equipment from pressure spikes.

4. Power and Energy Sector

  • Used in thermal and nuclear power plants for safe fluid control.

  • Supports high-pressure pipelines with slow closure mechanisms.

5. Case Study Table

IndustryApplicationObserved Benefit
Municipal WaterPumping station pipelinesReduced water hammer and extended pump life
HVAC SystemsChilled water circuitsStable flow, quieter operation
Chemical PlantAcid and alkali pipelinesCorrosion resistance, controlled closure
Power PlantCooling water loopsEquipment protection, system efficiency

Advantages Over Conventional Check Valves

FeatureMicro Resistance Slow Lockup ValveStandard Check Valve
Closure SpeedControlled slow lockupInstant closure
Water Hammer ProtectionHighLow
Pressure DropLowModerate
MaintenanceMinimal, easy to inspectStandard maintenance required
System EfficiencyHigh due to stable flowModerate

Conclusion

The Micro Resistance Slow Lockup Check Valve is a high-precision, energy-efficient solution for industrial and municipal fluid systems requiring backflow prevention, water hammer mitigation, and stable system performance. Its durable construction, micro resistance design, and adherence to international testing standards make it ideal for applications across water supply, HVAC, industrial processing, and power generation.

Proper installation, regular maintenance, and material compatibility ensure long-term performance and operational safety. For engineers and operators seeking a reliable, low-maintenance, and protective valve solution, the micro resistance slow lockup check valve represents a smart investment that enhances both system longevity and operational efficiency.

ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS